Performance Tests
|
|
Supported Tests
|
Torque, speed, current, voltage, input power, output power, time, efficiency, direction of rotation
|
Additional Tests
|
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging torque and back emf.
|
System Accuracy
|
± 0.2%
|
Torque Range
|
Not limited
|
Sensors
|
Industry standard. Accuracy: ± 0.3°.
|
|
|
Power Analyzer
|
Electronic Input
|
|
|
Voltage
|
110-230 V ± 10%
|
|
Frequency
|
50/60 Hz
|
|
Motor Input
|
|
|
Voltage Range
|
See table below.
|
|
Current Range
|
See table below.
|
|
Accuracy
|
± 0.2%
|
|
Performance Tests
|
|
Supported Tests
|
Torque, speed, current, voltage, input power, output power, time, efficiency, direction of rotation
|
Additional Tests
|
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging torque and back emf.
|
System Accuracy
|
± 0.2%
|
Torque Range
|
Not limited
|
Sensors
|
Industry standard. Accuracy: ± 0.3°.
|
|
Mechanical Specifications
|
Dimensions
|
26 x 12 x 33 cm (W x H x D)
|
|
Weight
|
10 kg (approx.)
|
|
|
|
|
Motor Holding Device
|
Dimensions
|
20 x 46 x 30 cm (W x H x D)
|
|
Weight
|
7 kg
|
|
Customizations
|
Customized devices available, according to customer's requirements
|
|
|
|
|
Calibration
|
|
|
|
Adjustments are made through calibration software interface. Calibration information is stored in the system database.
|
|
Model
|
Current*
|
Voltage
|
|
MLK-B-6010
|
0.06-10A
|
3-30/10-60/10-200/80-440
|
MLK-B-6025
|
0.08-25A
|
3-30/10-60/10-200/80-440
|
MLK-B-6050
|
0.2-50A
|
3-30/10-60/10-200/80-440
|
|
MLK-B-6100
|
3-100A
|
3-30/10-60/10-200/80-440
|
MLK-B-6200
|
6-200A
|
3-30/10-60/10-200/80-440
|
|
*Current Range: the minimum is for no load current and the maximum is for starting current. Please choose one or more Power Analyzers to cover your range of motors.
|
|