Performance Tests
 
 
Supported Tests
Torque, speed, current, voltage, input power, output power, time, motor efficiency, driver efficiency, direction of rotation
Additional Tests
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, friction output power, cogging torque level, and back EMF.
System Accuracy
± 0.2%
 
Torque Range
Not limited
 
Sensors
Industry standard. Accuracy: ± 0.3°.
 
 
 
 
Power Analyzer
Electronic Input
 
 
Voltage
110-230 V ± 10%
 
Frequency
50/60 Hz
 
Motor Input
 
 
Voltage Range
See table below.
 
Current Range
See table below.
 
Frequency
47-63 Hz
 
Accuracy
± 0.2%
 
 
 
 
Power Analyzer Name
Model
Current (*)
A
Voltage
V
PA 10 - 30/60/200/440
4010
0.06-10
3-30/ 10-60/ 10-200/ 80-440
PA 25 - 30/60/200/440
4025
0.08-25
3-30/ 10-60/ 10-200/ 80-440
PA 50 - 30/60/200/440
4050
0.2-50
3-30/ 10-60/ 10-200/ 80-440
PA 100 - 30/60/200/440
4100
3-100
3-30/ 10-60/ 10-200/ 80-440
PA 200 - 30/60/200/440
4200
6-200
3-30/ 10-60/ 10-200/ 80-440
 
 
 
 
(*)Current Range: the minimum is for no load current and the maximum is for starting current.
 
Please choose one or more Power Analyzers to cover you range of motors.
 
Mechanical Specifications
Dimensions
150 x 92 x 80 cm (W x H x D)
 
Weight
95 kg (approx.)
 
 
 
 
Motor Holding Device
Dimensions
20 x 46 x 30 cm (W x H x D)
 
Weight
7 kg
 
Customizations
Customized devices available, according to customer's requirements
 
 
 
 
Calibration
 
 
 
Adjustments are made through calibration software interface. Calibration information is stored in the system database.