Performance Tests |
|||||
Supported Tests |
Torque, speed, current, voltage, input power, output power, power factor, time, efficiency, frequency, direction of rotation |
||||
Additional Tests |
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum. |
||||
System Accuracy |
± 0.2% |
|
|||
Torque Range |
Not limited |
|
|||
Sensors
|
Industry standard. Accuracy: ± 0.3°. |
|
|||
|
|
|
|||
Power Analyzer |
|||||
Electronic Input |
|
|
|||
Voltage
|
110-230 V ± 10% |
|
|||
Frequency
|
50/60 Hz |
|
|||
Motor Input |
|
|
|||
Voltage Range |
24-280 V |
|
|||
Current Range |
See table below. |
|
|||
Frequency
|
47-63 Hz |
|
|||
Accuracy
|
± 0.2% |
|
|||
|
|||||
Model |
Current (*) A |
Voltage V |
|||
MLIK-C-3600 |
0.06-5 |
24-280 |
|||
MLIK-C-3601 |
0.06-10 |
24-280 |
|||
MLIK-C-3611 |
0.08-25 |
24-280 |
|||
MLIK-C-3621 |
0.2-50 |
24-280 |
|||
MLIK-C-3631 |
0.5-90 |
24-280 |
|||
|
|||||
(*) Current Range: the minimum is for no load current and the maximum is for starting current. Please choose one or more Power Analyzers to cover you range of motors. |
|||||
|
|||||
Mechanical Specifications |
|||||
Dimensions
|
26 x 12 x 33 cm (W x H x D) |
|
|||
Weight
|
10 kg (approx.) |
|
|||
|
|
|
|||
Motor Holding Device |
|||||
Dimensions
|
20 x 46 x 30 cm (W x H x D) |
|
|||
Weight
|
7 kg |
|
|||
Customizations
|
Customized devices available, according to customer's requirements |
|
|||
|
|
|
|||
Calibration |
|||||
|
Adjustments are made through calibration software interface. Calibration information is stored in the system database. |
|