Performance Tests

Supported Tests

Torque, speed, current, voltage, input power, output power, time, efficiency, direction of rotation

Additional Tests

Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging torque level, and back EMF

System Accuracy

± 0.2%

Torque Range

Not limited

Sensors

Industry standard. Accuracy: ± 0.3°. Optional: non-contact frictionless sensors.

 
 

Power Analyzer

Electronic Input

 
 
Voltage

110-230 V ± 10%

 
Frequency

50/60 Hz

 

Motor Input

 
 

Voltage Range

See table below.

 

Current Range

See table below.

 
Accuracy

± 0.2%

 
 

Model

Current (*)

A

Voltage

V

MLIK-DM-46010

0.06-10

3-30/ 10-60/ 10-200

MLIK-DM-46025

0.08-25

3-30/ 10-60/ 10-200

MLIK-DM-46050

0.2-50

3-30/ 10-60/ 10-200

 
 
 

MLIK-DM-46100

3-100

3-30/ 10-60/ 10-200

MLIK-DM-46200

6-200

3-30/ 10-60/ 10-200

MLIK-DM-46400

12-400

3-30/ 10-60/ 10-200

 
 
 

MLIK-DM-46600

18-600

3-30/ 10-60/ 10-200

MLIK-DM-46800

24-800

3-30/ 10-60/ 10-200

MLIK-DM-461200

36-1200

3-30/ 10-60/ 10-200

 

(*) Current Range: the minimum is for no load current and the maximum is for starting current.

 

Please choose one or more Power Analyzers to cover your range of motors.

 

Mechanical Specifications

Dimensions

26 x 12 x 33 cm (W x H x D)

 
Weight

10 kg (approx.)

 
 
 
 

Motor Holding Device

Dimensions

20 x 46 x 30 cm (W x H x D)

 
Weight

7 kg

 
Customizations

Customized devices available, according to customer's requirements

 
 
 
 

Calibration

 

Adjustments are made through calibration software interface. Calibration information is stored in the system database.

 

Performance Tests

Supported Tests

Torque, speed, current, voltage, input power, output power, time, efficiency, direction of rotation

Additional Tests

Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging torque level, and back EMF

System Accuracy

± 0.2%

Torque Range

Not limited

Sensors

Industry standard. Accuracy: ± 0.3°. Optional: non-contact frictionless sensors.

 
 

Power Analyzer

Electronic Input

 
 
Voltage

110-230 V ± 10%

 
Frequency

50/60 Hz

 

Motor Input

 
 

Voltage Range

See table below.

 

Current Range

See table below.

 
Accuracy

± 0.2%

 
 

Model

Current (*)

A

Voltage

V

MLIK-DM-46010

0.06-10

3-30/ 10-60/ 10-200

MLIK-DM-46025

0.08-25

3-30/ 10-60/ 10-200

MLIK-DM-46050

0.2-50

3-30/ 10-60/ 10-200

 
 
 

MLIK-DM-46100

3-100

3-30/ 10-60/ 10-200

MLIK-DM-46200

6-200

3-30/ 10-60/ 10-200

MLIK-DM-46400

12-400

3-30/ 10-60/ 10-200

 
 
 

MLIK-DM-46600

18-600

3-30/ 10-60/ 10-200

MLIK-DM-46800

24-800

3-30/ 10-60/ 10-200

MLIK-DM-461200

36-1200

3-30/ 10-60/ 10-200

 

(*) Current Range: the minimum is for no load current and the maximum is for starting current.

 

Please choose one or more Power Analyzers to cover your range of motors.

 

Mechanical Specifications

Dimensions

26 x 12 x 33 cm (W x H x D)

 
Weight

10 kg (approx.)

 
 
 
 

Motor Holding Device

Dimensions

20 x 46 x 30 cm (W x H x D)

 
Weight

7 kg

 
Customizations

Customized devices available, according to customer's requirements

 
 
 
 

Calibration

 

Adjustments are made through calibration software interface. Calibration information is stored in the system database.